[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: # Subject: [Killietalk] "U" tubes



Wright,

I have used a system similar to what you describe. It does work, though I found restarting the siphons (when needed) to be a pain. One note though is that my rack is right up against a wall, and so I don't have access to the back of the tanks. How I restarted siphons was by using another length of airline tubing that I would have a "connector piece" on the end... I filled that tubing up with water and then put the connector end into the siphon I was restarting. Lifting the length of tubing above the tank flushed the siphon free of air. Simple, cheap, but ultimately a little annoying to do.

Overflows (via bulkhead fittings) are just more error proof. Change the floss in the overflow once in a while, and that is it. No having to reach behind tanks, worry about babies being sucked out, etc. Though they are certainly more ugly. There are trade offs to everything I guess.

Mark
---------------------------------------------------
Mark Pearlscott, LMP
Treatment Massage, The Injury & Pain Relief Clinic
4500 9th Avenue NE, Suite 300-34, Seattle, WA 98105
http://www.TreatmentMassage.com
(206) 234-9929

"Assisting You to Wellness."
---------------------------------------------------


Wright Huntley wrote:
*"Curtis Smith" <cskillies at hotmail_com> wrote:*

Wright,

By all means use a length of airline tubing to start your siphon as it works well. Get good at it because from my experience with "u" tubes on a reef tank a few years ago they frequently lost their siphon and had to be re-started.

Curt



That would be a huge problem for an unattended continuous water change system to lose siphon. [Wet floors!] Besides, my "siphons" will be too tiny for that kind of start.


Since I probably will use 1/4" black drip irrigation tubing (with a clear airline section for monitoring), starting will be a minimal problem. Plug the outlet momentarily and suck with a baster on the upright opening to get it going. We are talking a double-J tube here, not the single over the tank edge kind. If continuously fed, it should be hard to lose siphon unless tank depth actually gets below the lower "U."

Clogging is a bigger problem than losing siphon, IMHO. I probably will cut a 2" long piece of 1/2" drip line and tap the 1/4" outgoing line into the center. Stuffed with floss, it should keep babies in and not clog very easily.

Wright



To join the AKA see http://www.aka.org/pages/join.html
Archives are at http://fins.actwin.com/killietalk/