Re: substrate heating



>From: William.Keith.Brummett at att_com
>Date: Wed, 19 Apr 1995 14:24:13 -0400 (EDT)
>
>    Is the actual heating element laying against the plastic backing, then?
>    I thought that the element was supposed to be suspended a half-inch or
>    so above the bottom to facilitate convection currents.

No. Maybe a picture will help.  Here is the elevation:

         Elevation       

     o  o  o  o  o  o  o   <--- Clothesline  
     ===================   <--- Clothesline
    ---------------------  <--- Carpet Backing

The plan would look like a grid with the carpet backing under it.  So
the heating coil will be held up off the ground by the thickness of
the clothesline - just under 1/4".

-Shaji