Re: [APD] Metal Halide lights on timers



Hmmm, these complications seem like one more strike against
those beautiful but expensive things called MH lamps.

But, they really shouldn't be blowing out timers, should
they?

Scott H.
--- Deepak Brid <deepak_apd at yahoo_com> wrote:
>  
> Hi Andrew,
>        With reference to the mail above,I'd suggest to
> use heavy duty relay contacter.
> This is what I've in planned for my MH setup,6500K Osram
> . Currently using 4x36W PLL,6000K Osram. Though My timer
> has not given me any trouble so far, still I would like
> to plan for the future Setup & design my Electrical
> console.
>  
>        In the figure below the TIMER is used to switch on
> a STEP DOWN TRANSFORMER ,which  trigger a Heavy Duty
> Relay CONTACTER which in turn switches ON the LOAD.
>  
>                        Timer          Step Down         
> Heavy Duty           To High 
>                        OUT           Transformer     
> Relay contacter          LOAD 
>  
>                   ________________Live___________________
>                   |                  |                   
>                            |
>                   |    ______    |                       
>     ________     |
>         LIVE-------|         _|---            (8)  |
> (8)---------||          _ ||----|
>                       |        \_|--Live--------(8)  |
> (8)        ||          \_ ||------------>Live   
>                       |           |               (8)  |
> (8)         ||             ||                         MH
> Ballast
> NEUTRAL-------|______|--Neu--------(8)  |
> (8)---------||_______||------------->Neutral
> 
>                    |               |                     
>          ^IN    OUT^   |
> 
>                    |               |                     
>                             |
>                   
> |_________|_____Neutral_________________ |
>  
>  Legend:
>  
> 1. TIMER - Any suitable Real Clock / Cyclic timer.
> 2. Heavy Duty Relay CONCTACTER - This has to be chosen
> appropriately w.r.t  the LOAD. (Eg:U pick up a Contacter
> with operating Voltage24V .U can get a
> 2-pole,4-pole,6-pole contacter, choose as per the number
> of equipments you'd want to switch U can either use the
> contacter to switch the Live wire & bypass the relay for
> Neutral between the equipments OR use a both the L & N
> thrrough the Relay )(My Plan:Use a 6-Pole Contacter with
> 12V operating voltage)
> 3. STEP DOWN TRANSFORMER - The transformer should be able
> to energize the CONTACTER. (Eg: the transformer should be
> able to drive the Contacter (CAUTIO
> N: Overdriving the Contacter can reduce its life).(My
> plan: Get a Torodial Transformer,low on heat & losses,
> made to order 12V, ampere as per the contacter
> requirement)
> 4. LOAD - U can then use a MH, PLL,CFL or Regular tube
> lights.
>  
>     This way one does not need to invest on a high load
> timer & since the LOAD in on the CONTACTER the the life
> expectancy of the timer is drastically improved.


=====
S. Hieber

__________________________________
Do you Yahoo!?
Yahoo! Hotjobs: Enter the "Signing Bonus" Sweepstakes
http://hotjobs.sweepstakes.yahoo.com/signingbonus
_______________________________________________
Aquatic-Plants mailing list
Aquatic-Plants at actwin_com
http://www.actwin.com/mailman/listinfo.cgi/aquatic-plants